Term
Why do you store the bottle of gonioscopic fluid in its container upside down and use proper lens filling technique?
Definition
To reduce the number of bubbles formed
Term
What effect does excess light have on a gonioscopy readings?
Definition
Minimal amounts of light constrict the pupil leading to a wider angle appearance than would occur in dark conditions.
Term
What type of iris is associated with hyperopia and has an increased risk of developing angle closure glaucoma?
Definition

Significantly Convex

Term
What shape of iris is associated with myopia and pigment dispersion syndrome?
Definition

concave

Term
What color is the ciliary body in gonioscopy and where is it?
Definition
Light gray to brown band just anterior to teh root of the iris.
Term
Do myopes or hyperopes have a wider ciliary body?
Definition
The ciliary body may be wide in myopes and narrow or absent in hyperopes.
Term
How does the scleral spur appear?
Definition
a thin white band
Term
What color does the trabecular meshwork appear to be?
Definition
tan to dark brown
Term

What is the most anterior structure of the angle and how does it appear?

Definition
Schwalbe's line and it appears as a refractile white line.
Term
Where is the angle usually largest in gonioscopy? 
Definition
inferiorly
Term
Where is the pigment densest?
Definition
inferiorly
Term
Where is the angle narrowest in gonioscopy?
Definition
superiorly
Term
What is one possible reason for bubbles in the gonioscopic fluid?
Definition
to little pressure is being placed on the eye
Term
What are the advantages of four mirrored gonioscopy compared to three mirrored gonioscopy?
Definition
1)  It is performed quickly
2)  Requires no rotation of the lens
3)  Allows for rapid comparison between the two eyes
4)  requires no gonioscopic fluid
5)  is smaller in size and may be better suited for patients with small palpebral apertures, and may be easier for patients to tolerate
6)  less traumatic to the globe, may be better in cases of ocular trauma or to assess acute angle closure glaucoma
7) 
Term
What are the disadvantages to gonioscopy?
Definition
maintaining proper positioning of the lens can be difficult to master because no suction is created between the lens and the cornea
Term
In what type of gonioscopy can you distinguish between synechial and appositional narrow angle glaucoma?
Definition
4 mirror
Term
How do you clear the cornea to allow for angle evaluation if a corneal edema develops secondary to an acute intraocular pressure elevation?
Definition
Instill 1 to 2 drops of topical opthalmic glycerin solution