Term
| WHEN TESTING RELIEF VALVES ON THE FIN STABILIZER, PUT GUAGES ON: |
|
Definition
|
TS4 AND TS5 ON THE MAIN HYDRAULIC DISTRIBUTION MANIFOLD.
|
|
|
Term
| WHEN REMOVING AIR IMPURITIES SUCH AS DUST, FUMES, SMOKE, AND VAPOR IS CALLED WHAT PROCESS? |
|
Definition
|
|
Term
| THE PROCESS OF MOVING STALE AIR AND PROVIDING FRESH AIR IS CALLED: |
|
Definition
|
|
Term
| THE MOVEMENT OF AIR THROUGH A NATURAL MEANS IS: |
|
Definition
|
|
Term
| IF THE DIFFERENCE BETWEEN Tw AND Ts IS OVER 4 DEGREES, THEN THE: |
|
Definition
|
INTAKE AIR IS BEING HEATED IN THE SUPPLY DUCT
|
|
|
Term
| IN DEMPS, WHAT SHALL BE PLOTTED ON GRAPH PAPER? |
|
Definition
|
CRANKCASE VACUUM, INTAKE AIR PRESSURE, EXHAUST PRESSURE, AND LUBE OIL CONSUMPTION
|
|
|
Term
| MAINTENANCE PERSONNEL SHALL KNOW THE NORMAL RUNNING TEMPS OF EACH BEARING UNDER ALL CONDITIONS OF: |
|
Definition
|
LOAD, SPEED, AND INVESTIGATE ANY CHANGES IMMEDIATLY.
|
|
|
Term
| SURFACE INSPECTIONS OF COMPRESSED AIR SYSTEMS ARE PERFORMED: |
|
Definition
|
SEMI-ANNUALLY (EVERY 6 MONTHS)
|
|
|
Term
| A PHYSICAL INVENTORY IS TAKEN TO VERIFY THE EXISTENCE OF A SPECIFIC STOCK ITEM IS CALLED A: |
|
Definition
|
|
Term
| REVERSE OSMOSIS SYSTEMS SHOULD BE QUIET AND FREE FROM EXCESSIVE: |
|
Definition
|
VIBRATIONS, CLICKING OR METALLIC NOISES
|
|
|
Term
| FAILURE TO REMOVE CLEANING FLUIDS FROM SEALING SURFACES COULD CAUSE: |
|
Definition
|
SOME "O"RINGS TO SWELL AND INTERFERE WITH PERFORMANCE OR CAUSE SEAL FAILURE.
|
|
|
Term
| IF YOU LOSE SUCTION ON A P-250 PUMP DUE TO LEAKY HOSE: |
|
Definition
|
REPAIR OR REPLACE SUCTION HOSE
|
|
|
Term
| IF WATER PRIMING PUMP ON P-250 WON'T PRIME: |
|
Definition
|
IT IS NOT A BAD FUEL LINE.
|
|
|
Term
| THERE SHOULD BE NO MORE THAN ____ INCHES Hg OF VACUUM LOST IN 10 MINUTES ON A P-250 VACUUM TEST |
|
Definition
|
|
Term
| IF P-250 ENGINE MISFIRES IT COULD BE THE: |
|
Definition
|
VRO PUMP (VARIO RATIO OILER)
|
|
|
Term
| TO TEST RESISTANCE ON A CHARGE COIL, CALIBRATE OHMETER TO A MEDIUM: |
|
Definition
|
|
Term
| TO CHECK IF CHARGE COIL IS SHORTED TO GROUND, CALIBRATE OHMMETER TO HIGH: |
|
Definition
|
|
Term
| TO CHECK SENSOR COIL RESISTANCE, CALIBRATE OHMMETER TO A MEDIUM: |
|
Definition
|
|
Term
| TO CHECK IF SENSOR COIL IS SHORTED TO GROUND, CALIBRATE OHMMETER TO A HIGH |
|
Definition
|
|
Term
| CHARGER COIL RESISTANCE READINGS SHOULD BE: |
|
Definition
|
|
Term
| IF SLUGGING OCCURS IN THE EVAP YOU: |
|
Definition
|
REDUCE INJECTION RATE BY 40-50%
|
|
|
Term
| IF SCALING OCCURES IN THE EVAP YOU: |
|
Definition
|
INCREASE INJECTION RATE BY 40-50%
|
|
|
Term
| IF WASHER DOES NOT DRAIN DUE TO MANIFOLD AIR LOCK: |
|
Definition
|
ENSURE BLEED HOLE IS CLEAR.
|
|
|
Term
| TEST THE BRAKES ON A DAVIT BY HOLDING THE LOAD STATIONARY FOR AT LEAST: |
|
Definition
|
|
Term
| FOR STATIC LOAD TEST OF A DAVIT SUSPENDED THE TEST WEIGHT FROM THE BOAT HOOK FOR A PERIOD OF: |
|
Definition
|
|
Term
| THE STATIC LOAD TEST IS PERFORMED AT ___ OF THE DAVIT'S RATED LOAD: |
|
Definition
|
|
Term
| THE DYNAMIC LOAD TEST IS PERFORMED AT ___ OF THE DAVIT'S RATED LOAD: |
|
Definition
|
|
Term
| THE RATED LOAD TEST IS PERFORMED AT ___ OF THE DAVIT'S RATED LOAD: |
|
Definition
|
|
Term
| THIS CHEMICAL IS USED TO DISINFECT POTABLE WATER: |
|
Definition
|
CALCIUM HYPOCHLORITE (HTH)
|
|
|
Term
| THE WATER TESTS ARE IMPORTANT BECAUSE SAFETY OF THE WATER IS DEPENDANT ON: |
|
Definition
|
RESIDUAL CONCENTRATIONS OF FREE AVAILABLE CHLORINE (FAC) OR BROMINE
|
|
|
Term
| THESE ARE REQUIRED ONLY IN EXHAUST DUCTS FROM COMPARTMENTS THAT COULD PRODUCE EXPLOSIVE VAPORS: |
|
Definition
|
|
Term
| CAREFULLY REMOVE THE STEAM FEED HEATER TO PREVENT DAMAGE TO THE: |
|
Definition
|
|
Term
| WHEN ON THE EXECUTIVE COMMAND BAR, TYPE ___ ___ AND PRESS RETURN. |
|
Definition
|
|
Term
| THIS SYSTEM IS DESIGNED TO SUPPORT A CUTTER'S MISSION: |
|
Definition
|
|
Term
| ON LEVEL II INSPECTION AND OVERHAUL TEST PADEYES TO: |
|
Definition
|
200% OF THE DESIGNED WORKING LOAD
|
|
|
Term
| RECIRC. SERVICE TANKS THROUGH HOSE AND FILTER/SEPERATOR FOR ___ AND THROUGH THE NOZZLE FOR ___ BEFORE TAKING "CLEAR AND BRIGHT" AND/OR WATER AND SEDIMENT TEST: |
|
Definition
|
1 HOUR/ AT LEAST 5 MINUTES
|
|
|
Term
| WHAT ARE THE TWO MOST WIDELY USED BEARING PULLERS IN THE CG? |
|
Definition
|
|
Term
| WHO SIGNS THE DD 1149 FOR ANYTHING OTHER THAN BULK FUEL: |
|
Definition
|
|
Term
| THE CSMP'S ARE USED FOR REQUESTING: |
|
Definition
|
MAINTENANCE AND REPAIRS FOR AFLOAT UNITS
|
|
|
Term
| QUALIFICATION LETTERS ARE FILED WHERE: |
|
Definition
|
PERSONAL DATA RECORD (PDR)
|
|
|
Term
| UNDER A LOAD THE P-5 WILL RUN FOR: |
|
Definition
|
1.5-2.5 HOURS ON A GALLON OF GAS
|
|
|
Term
| WHEN CHECKING IF IGNITION COIL IS SHORTED TO GROUND ON A P-250, RESISTANCE SHOULD READ |
|
Definition
|
|
Term
| WHAT INSTRUCTION PROVIDES AUTHORITY TO DIVERT WASTES OVERBOARD WHILE WITHIN RESTRICTED WATERS WITHOUT VIOLATING FEDERAL, STATE, OR LOCAL LAWS? |
|
Definition
|
|
Term
| HOW MUCH OIL OF AN OIL SAMPLE FOR AN OIL INSPECTION OF A WARPING CAPSTAN SHOULD YOU TAKE: |
|
Definition
|
|
Term
| FOR PUMP ALIGNMENT SHIMS SHALL BE MADE FROM: |
|
Definition
|
|
Term
| ORDER OF PRECEDENCE WHEN OREDRING SUPPLIES: |
|
Definition
|
1) AGENCY INVENTORY, 2) EXCESS PROPERTY, 3) FEDERAL PRISON INDUSTRIES
|
|
|
Term
| A PHYSICAL INVENTORY IS TO: |
|
Definition
|
ENSURE ACCURACY OF RECORDS
|
|
|
Term
| WHEN STARTING A REEFER COMPRESSOR, JOG THE COMPRESSOR SEVERAL TIMES TO REMOVE: |
|
Definition
|
|
Term
| WHAT TYPE OF OIL IS USED IN THE FIN STABILIZER? |
|
Definition
|
|
Term
| ON A STEERING RAM, HOW MUCH OIL LEAKAGE IS ALLOWED? |
|
Definition
|
1/2 PINT DURING A 24 HOUR PERIOD
|
|
|
Term
| IN THE AFT NFU MODE, SET THE MOTOR CONTROLLER TO THE: |
|
Definition
|
|
Term
| AFTER REMOVING THE FIRING HEAD FROM THE BOILER, INSPECT THE: |
|
Definition
|
|
Term
| ACTIVITY, WEIGHT, AND DATE ARE REQUIRED ON THE LABEL PLATE, NOT THE: |
|
Definition
|
|
Term
| CLEAN THE PHOTOCONDUCTIVE LENS ON A BOILER WITH A: |
|
Definition
|
|
Term
| VISUAL INSPECTION, DETECTOR KIT, AND LABORATORY ANALYSIS ARE APPROVED TESTS FOR JP-5 NOT: |
|
Definition
|
|
Term
| THIS IS NOT A CAUSE OF NOISE OR VIBRATION OF A FIXED FIRE PUMP: |
|
Definition
|
TOO BIG OF A SUCTION LIFT
|
|
|
Term
| WHEN ADDING FLUID TO A HYDRAULIC SYSTEM, USE A FILTER WITH A NOMINAL RATING OF: |
|
Definition
|
|
Term
| ON THE OWS THE CYCLING EFFECT IS INDICATED BY RAPID CHANGES IN THE PRESSURE READINGS ON THE: |
|
Definition
|
OUTLET PRESSURE OF THE PRE-FILTER STAGE AND THE OUTLET PRESSURE OF THE FIRST STAGE SEPERATOR
|
|
|
Term
| THE AIR REGULATOR ON AN OWS IS SET AT: |
|
Definition
|
|
Term
| THE PRESSURE RELIEF VALVE ON AN OWS IS USED TO PREVENT THE OIL/WATER PUMP DISCHARGE PRESSURE FROM EXCEEDING: |
|
Definition
|
|
Term
| A MECHANICAL SEAL IS A SEAL DEVICE IN WHICH SEALING ACTION IS AIDED BY: |
|
Definition
|
|
Term
| WIPE "O"RINGS TO PREVENT: |
|
Definition
|
SHRINKAGE AND SEAL FAILURE
|
|
|
Term
| LAST THING TO BE SECURED WHEN RETURNING SYSTEM TO NORMAL AFTER HOT GAS DEFROSTING: |
|
Definition
|
DE-ENERGIZE ELECRIC HEATING CABLES
|
|
|
Term
| TO SECURE REFRIGERANT GOING TO THE EVAPORATOR COIL YOU CLOSE THE: |
|
Definition
|
|
Term
| ___ ARE PRIMARY IDEAS OR STEPS NECESSARY TO REACH THE OBJECTIVES SHOULD BE ARRANGED AND PRESENTED IN A LOGICAL ORDER. |
|
Definition
|
|
Term
| WHAT IS THE OBJECTIVE OF A LESSON PLAN? |
|
Definition
|
IT IS A DOCUMENT DESCRIBING HOW A TRAINING LESSON WILL BE PRESENTED
|
|
|
Term
| DO NOT MIX HYDRAULIC FLUID BECAUSE THEY MAY HAVE: |
|
Definition
|
|
Term
| REPLACE THE CONDENSOR IF OVER ___ OF THE TOTAL TUBES OR ___ OF THE TUBES IN ANY ONE PASS NEED TO BE PLUGGED OR REPLACED DUE TO CORROSION. |
|
Definition
|
|
Term
| WHAT IS LOCATED BETWEEN THE OUTLET PRESSURE GAUGE FOR THE PRE-FILTER STAGE AND THE OUTLET PRESSURE GAUGE FOR THE FIRST STAGE SEPERATOR? |
|
Definition
|
|
Term
| WHEN WORKING ON WATER COOLED CONDENSORS, BE CAREFUL NOT TO DAMAGE THE GASKETS BETWEEN THE: |
|
Definition
|
TUBE SHEETS AND THE WATERSIDE OF THE WATER HEADS
|
|
|
Term
| HYDROSTATIC PRESSURE TEST FOR AIR SYSTEMS ON SHIP'S BUILT BEFORE 1969 SHALL NOT EXCEED THE: |
|
Definition
|
VALUE SPECIFIED ON ORIGINAL SYSTEM DRAWINGS OR 150% OF THE NORMAL OPERATING PRESSURE
|
|
|
Term
| AIR SYSTEMS BUILT AFTER 1969, THE TEST PRESSURE IS: |
|
Definition
|
|
Term
| ON A REFRIGERATION SYSTEM, TURN THIS ON WHEN SECURED TO EVAPORATE REFRIGERANT TRAPPED INSIDE THE OIL: |
|
Definition
|
COMPRESSOR CRANKCASE HEATER
|
|
|
Term
| BRUSH THE TUBES ON THE FIRESIDE OF A BOILER WITH THE: |
|
Definition
|
|
Term
| TO REMOVE LOOSE SOOT FROM THE FIRESIDE OF A BOILER USE: |
|
Definition
|
INDUSTRIAL TYPE VACUUM CLEANER
|
|
|
Term
| TO CLEAN THE INSULATION OF THE FIRESIDE, USE A: |
|
Definition
|
|
Term
| TO REMOVE SCALE FROM THE WATERSIDE OF A BOILER USE: |
|
Definition
|
HIGH PRESSURE (50-60 PSI) WATER HOSE
|
|
|
Term
| RIGGING GEAR MUST BE TESTED TO: |
|
Definition
|
1 1/2 TIMES ITS SAFE WORKING LOAD EACH YEAR
|
|
|
Term
| TOTAL HP OF ENGINE BEING INSTALLED SHOULD BE NO LESS THAN: |
|
Definition
|
70% OF BOATS CERTIFICATION PLATE
|
|
|
Term
| TILT CYLINDER MOVES ENGINE THROUGH THE FINAL: |
|
Definition
|
50 DEGREES OF MOTION (TILT RANGE)
|
|
|
Term
| THREE METHODS OF REPORTING PROJECTS FOR SSMP'S: |
|
Definition
|
SHORE STATION MAINT. RECORD (SSMR), CASUALTY REPORT (CASREP), MESSAGE/LETTER.
|
|
|
Term
| WHAT FORM IS USED EXTENSIVELY BY CG ORDANCE DEPARTMENTS: |
|
Definition
|
|
Term
| THE THREE BASIC TYPES OF REVISIONS ARE: |
|
Definition
|
REISSUE, PAGE REPLACEMENT, PEN CHANGE
|
|
|
Term
| ORDER OF PRIORTY WHEN SERVICES: |
|
Definition
|
PURCHASE FROM BLIND, MANDATORY FEDERAL SUPPLY SCHEDULE, OPTIONAL USER FEDERAL SUPPLY SCHEDULE, FEDERAL PRISON INDUSTRIES,INC.
|
|
|
Term
| THE REVERSE LOCK CHECK VALVE ALLOWS OIL TO FLOW FROM THE PUMP TO THE TOP SIDES OF THE TRIM/TILT CYLINDERS DURING: |
|
Definition
|
|
Term
| REPLACE PACKING WHEN LEAKAGE CAN NO LONGER BE CONTROLLED BY ADJUSTING THE: |
|
Definition
|
|
Term
| ON FUEL OIL PURIFIERS OPEN REGULATING VALVE (SV10) FOR DISPLACEMENT WATER: |
|
Definition
|
|
Term
| CLOSE PURIFIER SUCTION FOR HOW LONG PRIOR TO STOPPING UNIT: |
|
Definition
|
|
Term
| HOW MANY VOLTS IS APPLIED TO STARTED TO A STARTER UNIT FOR A HIGH VOLTAGE TEST: |
|
Definition
|
|
Term
| BOXES SHOULD BE DEFOSTED WHEN THE FROST BUILD-UP IS: |
|
Definition
|
|
Term
| BOXES MUST BE DEFOSTED WHEN THE FROST BUILD-UP IS: |
|
Definition
|
|
Term
| NEVER ALLOW FROST BUILD-UP TO EXCEED: |
|
Definition
|
|
Term
| IF PRESSURE DIFFERENTIALS OR THE CORRESPONDING DIFFERENCES INCREASE BY 30% |
|
Definition
|
THEN EVAP SHOULD BE ACID CLEANED.
|
|
|
Term
| WHEN HYDRO TESTING AN EVAP, TEST 10 PSIG AND HOLD FOR AT LEAST: |
|
Definition
|
|
Term
| WHEN TRANSFERING HYDRAULIC FLUID, ENSURE THAT THE FILTER ELEMENT USED HAS AN ABSOLUTE RATING OF ___ MICROMETERS, OR A NOMINAL RATING OF ___ MICROMETERS |
|
Definition
|
|
Term
| TO REMOVE TRAPPED AIR FROM A HYD. PUMP YOU: |
|
Definition
|
LOOSEN PUMP DISCHARGE FITTING AND JOG ON/OFF OR MANUALLY LIFT THE RELIEF VALVE AT THE DISCHARGE SIDE OF A PUMP.
|
|
|
Term
| HYDRAULIC FLUID SAMPLING CONTAINERS SHOULD BE: |
|
Definition
|
|
Term
| WHEN LAPPING A VALVE SEAT, USE THIS GRADE FOR VALVES THAT ARE NOT SEVERLY DAMAGED: |
|
Definition
|
|
Term
| WHILE CONDUCTING THE TEST ON MAGNA-MATIC EQUIPPED ENGINES SET THE TESTER GAP TO: |
|
Definition
|
|
Term
| ALL INFORMATION ON FIXED FIRE FIGHTING PUMPS CAN BE FOUND IN: |
|
Definition
|
|
Term
| CALCIUM HYPOCHLORITE MUST BE HANDLED AND STOWED IAW WITH: |
|
Definition
|
NSTM CHAPTER 670, STORAGE, HANDLING, AND DISPOSAL OF HAZARDOUS GENERAL USE CONSUMABLES
|
|
|
Term
| CHLORINE AND BROMINE ARE: |
|
Definition
|
HALOGENS FOR TREATING POTABLE WATER
|
|
|
Term
| THE THREE TESTS FOR ANCHOR WINDLASSES ARE: |
|
Definition
|
NO-LOAD, DROP, AND RECOVERY TEST
|
|
|
Term
| YOU MAINTAIN HOW MANY DEAD WRAPS ON A DRUM AT ALL TIMES: |
|
Definition
|
|
Term
| ON A FIRST LEVEL INSPECTION IF OIL IN GEARBOX IS MORE THAN FIVE GALLONS: |
|
Definition
|
SEND SAMPLE OUT FOR SPECTROANALYSIS INSPECTION
|
|
|
Term
| AIR SYSTEMS WITH MOISTURE SEPERATORS ARE REQUIRED METAL BOWLS: |
|
Definition
|
FOR SERVICE ABOVE 125 PSIG
|
|
|
Term
| IF THE DIFFERENCE BETWEEN Ts AND Ta IS OVER 10 DEGREES THEN: |
|
Definition
|
AIR QUANITY IS LOW OR THERE IS AN INFLUX OF HOT AIR FROM OTHER SPACES
|
|
|
Term
| ON A REVERSE OSMOSIS SYSTEM, DO NOT ADJUST THE SYSTEM TO EXCEED THE: |
|
Definition
|
RATED FLOW CAPACITY OR MAXIMUM OPERATING PRESSURE
|
|
|