        | Remove decay heat from the core and RCS during plant cool down and RFO. Transfer refueling water between RWST and Refuel Cavity.   ECCS: RWST- Cold Leg Injection Containment Sump- Cold Leg Recirc Containment Sump- SI and CH Pp Suction Containment Sump- Containment Spray Headers |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | Remove residual and sensible heat for plant cooldown; usually placed in service within 4 hours of Shut down when RCS pressure is < 375 psig and temp < 350F (mode 4); 350F to 140F in 22 hours (with only one loop in service the time will double.)   Piping and Valve Design Basis: Suction Piping 450 psig/400F Discharge Piping 600 psig/400F Pp Seals 350 F RCS Isolation Valves 2485 psig/650F   ECCS: Normally aligned to RWST and disch. to all 4 Cold Legs, RH 19s must be open to meet this phase (Injection Phase)   Takes a suction on the containment sump when RWST is depleted and Containment Sump has adequate inventory to support Pp operation during Recirc Phase. Discharge to cold legs Can Discharge to Hot Legs Supplies SI and Ch Pp suction Supplies 1 CS Header   RHR Shut off head is 170 psig RHR is required to achieve safe Shut down. System is used for cold Shut down outside MCR.   |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | Location- 45 Aux Bldg Design: Pressure 600 psig, Temperature 350F, Flow Normal 3000 gpm @ 151 psid, Flow Accident 4500 gpm @ 130 psid   Mechanical Seal Cooled by CCW   Power Supplied 21- 2A 4KV Vital Bus, 22- 2B 4 KV Vital Bus    Pp start: MCR Bezel CC1 Auto Start SEC SI Modes (I, III, IV). THERE ARE NO MODE 2 STARTS   Pp Trips: Bus Overload (motor overcurrent) Bus Diff (SEC Modes 2.3.4 have load strip)   Room Cooler Supplied by SW. |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | ECCS Pp suction source- Injection Make Up for Filling Refueling Cavity- Mode 6 Suction Source for CS 400,000 gallon capacity, vented to Aux Building Make up via CVCS   TS-3.5.5 limits Min Level- 364,500 gallons Boron Concentration- 2300-2500 ppm Temperature 35 F   RWST Heating Loop- Auto start/stop to maintain RWST between 40-45F, Heat trace maintain >50F, Alarm if temp is <40F, temp controller recieves input from AFWST.   Purification- Refueling water purification Pp SFP cooling demineralizer and filter Flow path can also purify cavity or transfer water from cavity to RWST   |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | Single Loop shell and U tube HX, designed to handle 1/2 the DBA load.   Shell (CCW) @ 150 psig and 200F Tubes (RHR/RCS) @ 600 psig and 400F |  | 
        |  | 
        
        | Term 
 
        | MOVs- RH4 RHR Pp Suction Valves Specs and Interlocks |  | Definition 
 
        | Normally open 55 Aux Bldg 87 Stroke Time  Power- 21RH4- A 230V AC VB; 22RH4- 2B 230V AC VB   Interlocks: Manual Operation of Associated Containment Sump Vlv (SJ44) must be fully closed to open RH4 (so you don't Pp RWST/RCS to the Containment Sump) Unit 2 has "Semi-Auto Swap Over" allows SJ44 to open and RH4 auto close. permissives: 
must ensure adequate Containment Sump LevelNeed 2/4 lvl transmitters in RWST to read Lo-Lo Alarmneed SI signal from SEC/SSPStransfer is "fast acting valves", both valves are only open for a short timeinterlocks in place to prevent loss of suction to RHR Pps |  | 
        |  | 
        
        | Term 
 
        | MOVs- SJ44 Containment Sump Isolation Valves Specs and Interlocks |  | Definition 
 
        | Normally Closed 45 Aux Bldg 35 sec stroke time Power 21SJ44- A 230V VB, 22SJ44 B 230 V VB Interlocks: Mannually Open- associated RH4 must be fully closed prevents mannually draining RWST to Containment Semi-Auto Swap- SI and 2/4 RWST Lo-Lo Level Alarm, auto opens if armed, associated RH4 closes when SJ44 is full open   Spurious opening at Power is prevented by lock out on RP 4 and by "not arming the valves"   |  | 
        |  | 
        
        | Term 
 
        | MOVs- SJ69 RWST to RHR Suction Valves Specs and Interlocks |  | Definition 
 
        | Normally Open 55 Aux Bldg 25 sec stroke time Power C 230V VB   Interlocks: Power Lock out switch on RP 4   This valve could inop RHR because its a single valve feeding both trains of RHR from the RWST  |  | 
        |  | 
        
        | Term 
 
        | MOVs- RH29 Minimum Flow Valve Specs and Interlocks |  | Definition 
 
        | 45 Aux Bldg 30 sec Stroke time Power 21RH29-A 230V VB; 22RH29- B 230V VB   Auto Operation: Open <500 gpm with Pp breaker Closed Closes > 1150 gpm with Pp Breaker Open Valves must be in auto for RHR to be operable, must work as designed Valves don't Cycle due to 600 gpm Deadband If flow is < 500 gpm vlv will be open and stay open until it reaches > 1150 gpm. Interlocks- NONE    When RHR is in recirc there is no cooling to the Pp, therefore the Pps can heat up after a short period of time.     |  | 
        |  | 
        
        | Term 
 
        | With RHR Pp off (brkr open) what is the position of the 22RH29? |  | Definition 
 
        | Closed.   Valve closes >1150gpm, with Pp breaker open |  | 
        |  | 
        
        | Term 
 
        | With RHR Pp in service, reading 600 gpm flow, should the RH29's be open? |  | Definition 
 
        | No, because flow is >500 gpm, valve will open when flow is <500 gpm. |  | 
        |  | 
        
        | Term 
 
        | RH19s RHR Cross Connection Valves |  | Definition 
 
        | Normal Open 45 Aux Bldg 10 Sec Stroke Time Both valves must remain open to meet TS 3.5.2 for injection, ensures that either Pp can inject into all 4 loops/cold legs   Valves must be closed in Recirc Phase, to separate trains and supply different loads (SI Pp, CH Pps, CS Pp)   Power supply 21RH19, A 230V VB, 22RH19 B 230V VB   Interlocks: None |  | 
        |  | 
        
        | Term 
 
        | 21SJ 45 Specs and Interlocks |  | Definition 
 
        | Normally Closed 84 Aux Bldg 10 sec stroke time Manually opened when in recirc phase Power Supply 21SJ44 A 230V VB   Interlocks: 
21SJ44 must be full open to align to containment recircRH1 or RH2 must be fully closed, so you don't align to normal SD cooling path2SJ67 or 2SJ68 SI Pp Recirc to RWST must be fully closed. So you don't align the containment sump to the RWST |  | 
        |  | 
        
        | Term 
 
        | 22SJ45 RHR to SI/CH Pp Suction |  | Definition 
 
        | Normally Closed 84 Aux Bldg 10 sec stroke time Power Supply 22SJ44 B 230V VB   Interlocks: 
22SJ44 must be full open to align to containment recircRH1 or RH2 must be fully closed, so you don't align to normal SD cooling path2SJ67 or 2SJ68 SI Pp Recirc to RWST must be fully closed. So you don't align the containment sump to the RWST |  | 
        |  | 
        
        | Term 
 
        | 21/22SJ113's SI Pp suction cross connection valves |  | Definition 
 
        | normally closed, 10 sec stroke time 84 aux, Power 21SJ113 A 230V VB, 22SJ113 B 230V VB Interlocks: None Only need one valve to open, as they run parallel |  | 
        |  | 
        
        | Term 
 
        | SJ49's RHR to Cold Leg Injection Valves |  | Definition 
 
        | Normally open, 78 mech pen, 10 sec stroke time 21SJ49 supplies 21 and 23 Cold Legs 22SJ40 Supplies 22 and 24 Cold Legs Power supply 21SJ49 A 230V VB, 22SJ49 B 230V VB Interlocks: Power Lock out switches in RP4, prevents inadvertent closure, must be used to close valves. |  | 
        |  | 
        
        | Term 
 
        | RH26 Hot Leg Injection Valve |  | Definition 
 
        | Normally Closed 78 Containment Not normal flow path for EOPs, used in AB LOCA if hot leg injection is required and SI Pp is not available. Power is C 230V VB Interlocks: Power Lock out switch on RP4, prevent inadvertent opening , also has a key interlock prior to opening the valve |  | 
        |  | 
        
        | Term 
 
        | CS 36 RHR to Containment Spray |  | Definition 
 
        | Normally Closed 78 Inner Pen 10 sec stroke time used to supply CS to header when RWST is empty, and on Recirc Power Supply 21CS36 A 230V VB, 22CS36 B 230V VB Interlocks: Associated with SJ44 must be open RH1/2 must be closed 2500 gpm for full CS flow |  | 
        |  | 
        
        | Term 
 
        | RH18s RHR HX Discharge Valves |  | Definition 
 
        | Normally open, failed open, no CA to valve Failure Modes FAI, loss of air, FO on loss of control power controls through respective HX used in conjunction with RH20 HX bypass to control cooldown rate while maintaining RHR flow within operating band   While at power, if you restore CA to this valve you inop RHR. |  | 
        |  | 
        
        | Term 
 | Definition 
 | 
        |  |