| Term 
 
        | SRV 
 Describe the SRV purpose.
 |  | Definition 
 
        | Designed to maintain Rx pressure below the ASME code limit of 110% of vessel design pressure (110% x 1250psig = 1375psig). |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the SRV self actuation setpoint.
 |  | Definition 
 
        | -1109psig +/- 1%. -30psig blowdown to 1079psig.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe an SRV being open affect on the Rx.
 |  | Definition 
 
        | -2 bore sizes for the SRVs. -Rated at approx. 800,000lbm/hr each.
 -1 SRV open drops Rx level at 20"/min.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the bellows high pressure.
 |  | Definition 
 
        | -5 psig. -Renders safety function inoperable.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the tailpipe alarm setpoint.
 |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the concern from pilot leakage.
 |  | Definition 
 
        | Could cause a spurious lift of an SRV. |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the pneumatic supply to SRVs.
 |  | Definition 
 
        | -All normally supplied by instrument N2. -All non-safety B/U is instrument air.
 -SRVs A,B,E safety B/U is 'A' Alt N2.
 -SRVs C,F,H safety B/U is 'B' Alt N2.
 -SRVs D,G safety B/U is accumulators.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe which SRVs are on which MSLs.
 |  | Definition 
 
        | -A has A and E. -B has G and B.
 -C has H and C.
 -D has D and F.
 All good heavy dogs eat big chewy frogs for inboard outboard.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the ADS initiation signals.
 |  | Definition 
 
        | -Low low Rx level of -47". -A/C interlock met (100# on discharge of ECCS pump).
 -107 second timer timed out.
 -These are and statement.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the operation of ADS for different signals.
 |  | Definition 
 
        | -Timer resets if water level rises above -47" while timer is running. -Once timer has runout, ADS seals in.
 -Inhibit switches stop ADS anytime.
 -Loss of the A/C interlock stops ADS anytime.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe which SRVs are on ADS.
 |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe which SRVs are on lo lo set.
 |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe ADS logic power.
 |  | Definition 
 
        | -Bus A: 125Vdc D-11 Ckt 10. -Bus B: 125Vdc D-21 Ckt 12 (Bus A is b/u).
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe SRV solenoid power.
 |  | Definition 
 
        | -Bus A: D-11. -Bus B is backup: D-21.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the purpose of lo lo set.
 |  | Definition 
 
        | Help prevent water from climbing up the SRV tail pipe and protecting primary containment. |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the lo lo set initiation signal.
 |  | Definition 
 
        | -Full SCRAM signal from both: -Div 1 A: backup scram valve energized.
 -Div 2 A & B: SDV vent and drain pilot valves de-energized.
 
 -Lo lo set in AUTO.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the effect of resetting a SCRAM on lo lo set.
 |  | Definition 
 
        | -Ability to use lo lo set is lost. |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the lo lo set SRV setpoints.
 |  | Definition 
 
        | -H: 1052#. -G: 1062#.
 -E: 1072#.
 -All have a 80# blowdown.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe lo lo set after a SRV has lifted.
 |  | Definition 
 
        | -Prevents reopening for any reason (except mechanical lift) for 10 seconds to ensure discharge line water leg clears. -Limits thermal hydraulics.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe how to tell if an SRV is open.
 |  | Definition 
 
        | -Signal of open w/ 30psid between drywell and tailpipe. |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe the indication lights for SRVs.
 |  | Definition 
 
        | -Green indicates solenoid valve is de-energized. -Amber indicates that 30psid exists in tailpipe.
 -Red indicates power supplied to solenoid.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe where SRVs can be operated from.
 |  | Definition 
 
        | -A through D (A,C,D are ADS) can only be operated from C-03. -A,C,D have OPEN and AUTO positions.
 -B has OPEN and CLOSED positions.
 -E,F,G,H (E,G,H are lo lo set) can be operated from C-03, C253-D and ASDS.
 -E,G,H have AUTO, OPEN and CLOSED on C-03 and ASDS.
 -E,G,H have AUTO and CLOSED only on C253-D.
 -F has CLOSE and OPEN only on all 3 panels.
 |  | 
        |  | 
        
        | Term 
 
        | SRV 
 Describe how many solenoids on each SRV.
 |  | Definition 
 
        | -A through D have 1 solenoid each. -E through H have 2 solenoids each.
 |  | 
        |  |