| Term 
 
        | What is the minimum voltage required to close the battery relays to connect the batteries to the battery charging bus? |  | Definition 
 
        | 16 VDC (CAE number) 
 7 VDC to 18 VDC (Bombardier numbers)
 |  | 
        |  | 
        
        | Term 
 
        | What are the minimum battery voltages for start? |  | Definition 
 
        | Nicad= 23 VDC 
 Lead Acid= 24 VDC (25 VDC if over 110 degrees F)
 |  | 
        |  | 
        
        | Term 
 
        | If both 275 amp current limiters fail, what effect will this have on the electrical system? |  | Definition 
 
        | The generators can not recharge the batteries.  All items connected to the Battery Charging Bus including essential buses on aircraft without AMK 85-1 (SN 35-509 and below) will continue to operate until the batteries are depleted. Ammeters will indicate normal system draw. Voltmeter will indicate battery voltage. |  | 
        |  | 
        
        | Term 
 
        | If the Left Main Bus and the Main Bus tie circuit breakers have opened, what has possibly happened? |  | Definition 
 
        | The Left Main Bus has a fault and has been isolated from the electrical system |  | 
        |  | 
        
        | Term 
 
        | What buses and inverter are connected to the Right Generator Bus? |  | Definition 
 
        | Right Power, Right Main, and Battery Charging Bus and Secondary Inverter |  | 
        |  | 
        
        | Term 
 
        | What event disengages the starter and opens the second serial start relay? |  | Definition 
 
        | 45% N2 or 50% N2 depending on fuel computers installed 
 45% N2 SN 35-245+ and prior aircraft with 1142 fuel computers
 |  | 
        |  | 
        
        | Term 
 
        | What are the load limitations on the gernerators? |  | Definition 
 
        | 320A on the ground 
 400A in the air
 |  | 
        |  | 
        
        | Term 
 
        | The DC circuit breakers are what type? |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | What DC buses are "HOT" all the time and what systems are connected to them? |  | Definition 
 
        | DC Left Battery Bus: Left Stall Entrance Lights
 Door Motor
 
 DC Right Battery Bus: Right Stall
 |  | 
        |  | 
        
        | Term 
 
        | What is the maximum allowable amperage from the ground power unit? |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | What is the minimum allowable amperage from the ground power unit? |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | How could you tell if a 50A current limiter is blown during the preflight? |  | Definition 
 
        | A silver pin protrudes from the top of the current limiter |  | 
        |  |