| Term 
 | Definition 
 
        | The bread and butter of the fire service. The most common type of fire apparatus, it is a part of almost every fire department. |  | 
        |  | 
        
        | Term 
 
        | 750 GPM's, minimum of 300 gallons |  | Definition 
 
        | Per NFPA 1901 a pumper must be equipped with a permanently mounted pump with a minimum rating of what? And a minimum of how many gallons in its water tank? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | From a standing start, the apparatus must be able to attain a speed of what? and within how many seconds on a level road? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | The apparatus must be able to attain a minimum top speed of what on a level road? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | The apparatus must be able to maintain a speed of at least what on any grade up to and including 6 percent? |  | 
        |  | 
        
        | Term 
 
        | 800ft of 2 1/2-inch or larger supply/attack hose 400ft of 1 1/2, 1 3/4, or 2-inch attack hose
 One combination spray nozzles capable of delivering 200 GPM at a minimum
 Two combination spray nozzles capable of delivering 95GPM at a m minimum
 One play pipe, with shut-off and 1-inch 1 1/8-inch and 1 1/4-inch tips.
 |  | Definition 
 
        | Per NFPA 1901 What following types of fire hose and nozzles are required on a pumper fire apparatus? |  | 
        |  | 
        
        | Term 
 
        | one straight ladder with roof hooks, one extension ladder, and one attic ladder |  | Definition 
 
        | What type of ladders and how many are on a Pumper fire apparatus? |  | 
        |  | 
        
        | Term 
 
        | Initial attack fire apparatus |  | Definition 
 
        | What apparatus is more maneuverable than the pumper and has four wheeled drive? |  | 
        |  | 
        
        | Term 
 
        | Minimum rated capacity of 250GPM and a water with a minimum of 200 gal. |  | Definition 
 
        | What is the minimum rated capacity of a Initial attack fire apparatus? and what is the minimum tank size? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum size enclosed weather resistant compartment on a pumper fire apparatus? |  | 
        |  | 
        
        | Term 
 
        | -300ft of 2 1/2-inch or larger fire supply hose -400ft. of 1 1/2 inch, 1 3/4 inch, or 2 inch attack fire hose
 -Two combination spray nozzles with a minimum capacity of 95GPM.
 |  | Definition 
 
        | What are the minimum fire hose and nozzles on a Initial Attach Fir Apparatus? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum weather resistant enclosed compartment on a Initial attack Fire Apparatus? |  | 
        |  | 
        
        | Term 
 
        | 12ft. or longer combination or extension type ladder. |  | Definition 
 
        | What ladder is carried on a Initial attack fire apparatus? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What NFPA is Standard for Manufactures Design of Fire department Ground Ladders? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | If a Mobile water Supply Apparatus is equipped with a pump. It must meet the criteria in what chapter of NFPA 1901? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum enclosed compartment capacity on a Mobil water Supply Apparatus? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum total complement of ground ladders that must be on a Aerial Fire apparatus? |  | 
        |  | 
        
        | Term 
 
        | One attic ladder, two straight ladders with roof hooks, and two extension ladders. |  | Definition 
 
        | What is the minimum number and type of ladders that must be on an Aerial fire apparatus according to NFPA 1901? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum enclose compartment space for a Aerial Fire Apparatus? |  | 
        |  | 
        
        | Term 
 
        | Pump, Water tank, Fire hose storage, aerial, ground ladders |  | Definition 
 
        | What are the five functions on a Quint? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the pump rated capacity on a Quint? and what is the minimum water tank certified capacity? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum total complement of ground ladders a Quint must hold? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum enclosed compartment storage on a Quint? |  | 
        |  | 
        
        | Term 
 | Definition 
 
        | What is the minimum enclosed compartment storage capacity on a Special Service Fire apparatus? |  | 
        |  |