| Term 
 
        | What components make up the DA42 electrical system? |  | Definition 
 
        | One 24VDC 10am hour battery Two 70 Amp alternators
 One alternator excitation battery
 Two ECU batteries
 One emergency battery to power the flood light and standby attitude indicator
 |  | 
        |  | 
        
        | Term 
 
        | How many electrical buses are there? |  | Definition 
 
        | Battery bus Hot battery Bus (powers pilot overhead light & ELT)
 LH main bus
 RH main bus
 R ECU bus
 L ECU bus
 Avionics bus
 |  | 
        |  | 
        
        | Term 
 
        | How many batteries are there, in total? |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | What equipment is not electrically powered? |  | Definition 
 
        | Standby altimeter and standby airspeed indicator |  | 
        |  | 
        
        | Term 
 
        | If the main battery and alternators fail, how long will the ECUs run on the dedicated battery? |  | Definition 
 | 
        |  | 
        
        | Term 
 
        | What is the procedure for handling a complete electrical failure? |  | Definition 
 
        | Circuit breakers - check in Emergency power switch - on
 Engine power - set by sound and approximate power lever position
 Land at nearest suitable airport
 |  | 
        |  | 
        
        | Term 
 
        | What is the procedure for handling an electrical fire in flight? |  | Definition 
 
        | Emergency power switch - ON Avionics master - OFF
 Electric master - OFF
 Cabin heat and defroster - OFF
 Emergency window - open as necessary
 Land at nearest suitable airport
 |  | 
        |  |